A Ratiometric Fluorescent Sensor Based on Chelation-Enhanced Fluorescence of Carbon Dots for Zinc Ion Detection
Guangrong Lu, Zhenzhen Jia, Mengdi Yu, Mingzhen Zhang, Changlong Xu- Chemistry (miscellaneous)
- Analytical Chemistry
- Organic Chemistry
- Physical and Theoretical Chemistry
- Molecular Medicine
- Drug Discovery
- Pharmaceutical Science
Zinc ion, one of the most important transition metal ions in living organisms, plays a crucial role in the homeostasis of the organism. The disorder of zinc is associated with many major diseases. It is highly desirable to develop selective and sensitive methods for the real-time detection of zinc ions. In this work, double-emitting fluorescent carbon dots (CDs) are prepared by a solvothermal method using glutathione, L-aspartic acid, and formamide as the raw materials. The carbon dots specifically recognize zine ions and produce a decrease in fluorescence intensity at 684 nm and an increase at 649 nm, leading to a ratiometric fluorescent sensor for zinc detection. Through surface modification and spectral analysis, the surface groups including carboxyl, carbonyl, hydroxyl, and amino groups, and C=N in heterocycles of CDs are revealed to synergistically coordinate Zn2+, inducing the structural changes in the emission site. The CDs can afford a low limit of detection of ~5 nM for Zn2+ detection with good linearity in the range of 0.02–5 μM, showing good selectivity as well. The results from real samples including fetal bovine serum, milk powder, and zinc gluconate oral solution indicated the good applicability of the CDs in the determination of Zn2+.