W Garabet, A Arnautovic, L Meurer, J Mulorz, JD Rembe, M Duran, JD Süss, H Schelzig, MU Wagenhäuser

Analysis of Determinants for Suture-mediated Closure Device Failure During EVAR Procedures

  • Cardiology and Cardiovascular Medicine
  • General Medicine
  • Surgery

Objective Endovascular aortic repair (EVAR) for elective and emergency infrarenal aortic pathologies is the primary approach for treatment nowadays. During such procedure, the suture-mediated closure device (SMCD) (Perclose ProGlideTM, Abbott Laboratories, Chicago, IL, USA) is commonly used. This study aimed to identify potential contributors for SMCD failure in a patient cohort of elective and emergency EVAR. Methods Archived medical records from patients who underwent EVAR for aortic pathologies in elective and emergency setting at the University Hospital Düsseldorf, Germany were included. Patient’s co-morbidities, access vessel morphologies and hemostasis-related blood parameters were evaluated on their association with SMCD failure applying different statistical methods. Results A total of 71 patients (139 femoral accesses) was included. The mean age was 73.5 ± 8.4 years. Overall SMCD failure rate was 4.3%, 4.1% for elective and 5.9% for emergency cases, respectively. Total procedure time was longer for the SMCD failure group (323 ± 117.8 min vs 171 ± 43.7 min). The calcification status of the common femoral artery (CFA), the diameter of the aortic bifurcation, and dual anti-platelet therapy (DAPT) on the medication plan prior to the procedure were associated with SMCD failure. Univariate binary logistic regression analysis nominated several potentially relevant predictors for SMCD failure who underwent subsequent multivariable binary logistic regression analysis. Here, DAPT on the medication plan was identified as being promising in predicting SMCD failure (OR 30.5), while anterior plaque formation in the CFA maintained as only statistically relevant determinant (OR 44.9). Conclusions This study confirms the CFA calcification status to be associated with SMCD failure. Although discontinued prior to endovascular treatment, DAPT was also found to be associated with SMCD failure. Our results may advocate to perform obligatory platelet testing prior to EVAR to maximize patient safety.

Need a simple solution for managing your BibTeX entries? Explore CiteDrive!

  • Web-based, modern reference management
  • Collaborate and share with fellow researchers
  • Integration with Overleaf
  • Comprehensive BibTeX/BibLaTeX support
  • Save articles and websites directly from your browser
  • Search for new articles from a database of tens of millions of references
Try out CiteDrive

More from our Archive