DOI: 10.3390/diagnostics14080835 ISSN: 2075-4418

Can Plasma Volume Determination in Cirrhosis Be Replaced by an Algorithm Using Body Weight and Hematocrit?

Martine Prütz Nørskov, Thormod Mønsted, Nina Kimer, Morten Damgaard, Søren Møller
  • Clinical Biochemistry

Background: Patients with cirrhosis often develop hyperdynamic circulation with increased cardiac output, heart rate, and redistribution of the circulating volume with expanded plasma volume (PV). PV determination is part of the evaluation of patients with cirrhosis, but gold-standard methods are invasive, expensive, and time-consuming. Therefore, other estimations of PV would be preferable, and the aim of this study was therefore to study if PV, as assessed by a simplified algorithm based on hematocrit and weight, can replace the gold-standard method. Methods: We included 328 patients with cirrhosis who had their PV assessed by the indicator dilution technique as the gold-standard method (PVI-125). Actual PV was estimated as PVa = (1 − hematocrit)·(a + (b·body weight)). Ideal PV was estimated as PVi = c · body weight, where a, b, and c are constants. Results: PVI-125, PVa, and PVi were 3.99 ± 1.01, 3.09 ± 0.54, and 3.01 ± 0.65 (Mean ± SD), respectively. Although PVI-125 correlated significantly with PVa (r = 0.72, p < 0.001), a Bland–Altman plot revealed wide limits of confidence. Conclusions: The use of simplified algorithms does not sufficiently estimate PV and cannot replace the indicator dilution technique.

More from our Archive