DOI: 10.1002/ccd.31064 ISSN: 1522-1946

Comparisons of noncoronary sinus pivot implantation (NCPI) and conventional method for transcatheter aortic valve replacement with self‐expanding valve in pure aortic regurgitation (PAR)

Lifan Yang, Shasha Chen, Xiaochun Zhang, Yuan Zhang, Daxin Zhou, Wenzhi Pan, Junbo Ge

Abstract

Background:

As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates.

Aims

The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR.

Methods

PAR patients who underwent TAVR with self‐expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre‐operative evaluation parameters and procedural and postoperative data of the two subgroups.

Results

The total patients’ mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was −1.7 + 1.0 and 5.2 + 6.7 mm in groups A and B (p < 0.001), respectively.

Conclusions

TAVR with a self‐expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.

More from our Archive